Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Nat Commun ; 13(1): 3716, 2022 07 01.
Article in English | MEDLINE | ID: covidwho-1984382

ABSTRACT

The COVID-19 pandemic triggered the development of numerous diagnostic tools to monitor infection and to determine immune response. Although assays to measure binding antibodies against SARS-CoV-2 are widely available, more specific tests measuring neutralization activities of antibodies are immediately needed to quantify the extent and duration of protection that results from infection or vaccination. We previously developed a 'Serological Assay based on a Tri-part split-NanoLuc® (SATiN)' to detect antibodies that bind to the spike (S) protein of SARS-CoV-2. Here, we expand on our previous work and describe a reconfigured version of the SATiN assay, called Neutralization SATiN (Neu-SATiN), which measures neutralization activity of antibodies directly from convalescent or vaccinated sera. The results obtained with our assay and other neutralization assays are comparable but with significantly shorter preparation and run time for Neu-SATiN. As the assay is modular, we further demonstrate that Neu-SATiN enables rapid assessment of the effectiveness of vaccines and level of protection against existing SARS-CoV-2 variants of concern and can therefore be readily adapted for emerging variants.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Humans , Luciferases , Membrane Glycoproteins/metabolism , Neutralization Tests , Pandemics , Spike Glycoprotein, Coronavirus , Viral Envelope Proteins
2.
J Appl Lab Med ; 7(3): 698-710, 2022 05 04.
Article in English | MEDLINE | ID: covidwho-1831206

ABSTRACT

BACKGROUND: Numerous serology assays are available for detection of SARS-CoV-2 antibodies but are limited in that only 1 or 2 target antigen(s) can be tested at a time. Here, we describe a novel multiplex assay that simultaneously detects and quantifies IgG antibodies to SARS-CoV-2 antigens, spike (S), nucleocapsid (N), receptor-binding domain (RBD), and N-terminal domain (NTD) in a single well. METHODS: Sensitivity was determined using samples (n = 124) from confirmed SARS-CoV-2 RT-PCR positive individuals. Prepandemic (n = 100) and non-COVID respiratory infection positive samples (n = 100) were used to evaluate specificity. Samples were analyzed using COVID-19 IgG multiplex serology assay from Meso Scale Discovery (MSD) and using commercial platforms from Abbott, EUROIMMUN, and Siemens. RESULTS: At >14 days post-PCR, MSD assay displayed >98.0% sensitivity [S 100% (95% CI 98.0%-100.0%); N 98.0% (95% CI 97.2%-98.9%); RBD 94.1% (95% CI 92.6%-95.6%); NTD 98.0% (95% CI, 97.2%-98.9%)] and 99% specificity (95% CI 99.3%-99.7%) for antibodies to all 4 antigens. Parallel assessment of antibodies to more than 1 antigen improved the sensitivity to 100% (95% CI 98.0%-100.0%) while maintaining 98% (95% CI 97.6%-98.4%) specificity regardless of the combinations used. When AU/mL concentrations of IgG antibodies from the MSD assay were compared against the corresponding IgG signals acquired from the single target commercial assays, the following correlations were observed: Abbott (vs MSD N, R2 = 0.73), Siemens (vs MSD RBD, R2 = 0.92), and EUROIMMUN (vs MSD S, R2 = 0.82). CONCLUSION: MSD assay offers an accurate and a comprehensive assessment of SARS-CoV-2 antibodies with higher sensitivity and equivalent specificity compared to the commercial IgG serology assays.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19/diagnosis , COVID-19 Serological Testing , Humans , Immunoglobulin G , Sensitivity and Specificity
3.
Arch Pathol Lab Med ; 145(10): 1212-1220, 2021 10 01.
Article in English | MEDLINE | ID: covidwho-1444461

ABSTRACT

CONTEXT.­: Emerging evidence shows correlation between the presence of neutralization antibodies (nAbs) and protective immunity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Currently available commercial serology assays lack the ability to specifically identify nAbs. An enzyme-linked immunosorbent assay-based nAb assay (GenScript cPass neutralization antibody assay) has recently received emergency use authorization from the Food and Drug Administration. OBJECTIVE.­: To evaluate the performance characteristics of this assay and compare and correlate it with the commercial assays that detect SARS-CoV-2-specific immunoglobulin G (IgG). DESIGN.­: Specimens from SARS-COV-2 infected patients (n = 124), healthy donors obtained prepandemic (n = 100), and patients with non-coronavirus disease 2019 (COVID-19) respiratory infections (n = 92) were analyzed using this assay. Samples with residual volume were also tested on 3 commercial serology platforms (Abbott, Euroimmun, Siemens). Twenty-eight randomly selected specimens from patients with COVID-19 and 10 healthy controls were subjected to a plaque reduction neutralization test. RESULTS.­: The cPass assay exhibited 96.1% (95% CI, 94.9%-97.3%) sensitivity (at >14 days post-positive PCR), 100% (95% CI, 98.0%-100.0%) specificity, and zero cross-reactivity for the presence of non-COVID-19 respiratory infections. When compared with the plaque reduction assay, 97.4% (95% CI, 96.2%-98.5%) qualitative agreement and a positive correlation (R2 = 0.76) was observed. Comparison of IgG signals from each of the commercial assays with the nAb results from plaque reduction neutralization test/cPass assays displayed greater than 94.7% qualitative agreement and correlations with R2 = 0.43/0.68 (Abbott), R2 = 0.57/0.85 (Euroimmun), and R2 = 0.39/0.63 (Siemens), respectively. CONCLUSIONS.­: The combined data support the use of cPass assay for accurate detection of the nAb response. Positive IgG results from commercial assays associated reasonably with nAbs presence and can serve as a substitute.


Subject(s)
Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Enzyme-Linked Immunosorbent Assay/methods , Immunoglobulin G/immunology , SARS-CoV-2/immunology , Adolescent , Adult , Aged , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19/epidemiology , COVID-19/virology , Child , Child, Preschool , Cohort Studies , Epidemics/prevention & control , Humans , Immunoglobulin G/blood , Middle Aged , Reproducibility of Results , SARS-CoV-2/genetics , SARS-CoV-2/physiology , Sensitivity and Specificity , Young Adult
4.
Virol J ; 18(1): 1, 2021 01 04.
Article in English | MEDLINE | ID: covidwho-1388776

ABSTRACT

BACKGROUND: Virus neutralization by antibodies is an important prognostic factor in many viral diseases. To easily and rapidly measure titers of neutralizing antibodies in serum or plasma, we developed pseudovirion particles composed of the spike glycoprotein of SARS-CoV-2 incorporated onto murine leukemia virus capsids and a modified minimal murine leukemia virus genome encoding firefly luciferase. This assay design is intended for use in laboratories with biocontainment level 2 and therefore circumvents the need for the biocontainment level 3 that would be required for replication-competent SARS-CoV-2 virus. To validate the pseudovirion assay, we set up comparisons with other available antibody tests including those from Abbott, Euroimmun and Siemens, using archived, known samples. RESULTS: 11 out of 12 SARS-CoV-2-infected patient serum samples showed neutralizing activity against SARS-CoV-2-spike pseudotyped MLV viruses, with neutralizing titers-50 (NT50) that ranged from 1:25 to 1:1,417. Five historical samples from patients hospitalized for severe influenza infection in 2016 tested negative in the neutralization assay (NT50 < 25). Three serum samples with high neutralizing activity against SARS-CoV-2/MLV pseudoviruses showed no detectable neutralizing activity (NT50 < 25) against SARS-CoV-1/MLV pseudovirions. We also compared the semiquantitative Siemens SARS-CoV-2 IgG test, which measures binding of IgG to recombinantly expressed receptor binding domain of SARS-CoV-2 spike glycoprotein with the neutralization titers obtained in the pseudovirion assay and the results show high concordance between the two tests (R2 = 0.9344). CONCLUSIONS: SARS-CoV-2 spike/MLV pseudovirions provide a practical means of assessing neutralizing activity of antibodies in serum or plasma from infected patients under laboratory conditions consistent with biocontainment level 2. This assay offers promise also in evaluating immunogenicity of spike glycoprotein-based candidate vaccines in the near future.


Subject(s)
COVID-19/immunology , Leukemia/immunology , Neutralization Tests/methods , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Virion/immunology , Angiotensin-Converting Enzyme 2/immunology , Animals , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , HEK293 Cells , Humans , Immunoglobulin G/blood , Mice
5.
Emerg Infect Dis ; 27(11): 2786-2794, 2021 11.
Article in English | MEDLINE | ID: covidwho-1381376

ABSTRACT

We aimed to generate an unbiased estimate of the incidence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in 4 urban counties in Utah, USA. We used a multistage sampling design to randomly select community-representative participants >12 years of age. During May 4-June 30, 2020, we collected serum samples and survey responses from 8,108 persons belonging to 5,125 households. We used a qualitative chemiluminescent microparticle immunoassay to detect SARS-CoV-2 IgG in serum samples. We estimated the overall seroprevalence to be 0.8%. The estimated seroprevalence-to-case count ratio was 2.5, corresponding to a detection fraction of 40%. Only 0.2% of participants from whom we collected nasopharyngeal swab samples had SARS-CoV-2-positive reverse transcription PCR results. SARS-CoV-2 antibody prevalence during the study was low, and prevalence of PCR-positive cases was even lower. The comparatively high SARS-CoV-2 detection rate (40%) demonstrates the effectiveness of Utah's testing strategy and public health response.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Humans , Probability , Seroepidemiologic Studies , Utah/epidemiology
6.
PLoS One ; 15(10): e0240783, 2020.
Article in English | MEDLINE | ID: covidwho-874204

ABSTRACT

BACKGROUND: Understanding and monitoring the demographics of SARS-CoV-2 infection can inform strategies for prevention. Surveillance monitoring has suggested that the age distribution of people infected with SARS-CoV-2 has changed since the pandemic began, but no formal analysis has been performed. METHODS: Retrospective review of SARS-CoV-2 molecular testing results from a national reference laboratory was performed. Result distributions by age and positivity were compared between early period (March-April 2020) and late periods (June-July 2020) of the COVID-19 pandemic. Additionally, a sub-analysis compared changing age distributions between inpatients and outpatients. RESULTS: There were 277,601 test results of which 19320 (7.0%) were positive. The median age of infected people declined over time (p < 0.0005). In March-April, the median age of positive people was 40.8 years (Interquartile range (IQR): 29.0-54.1). In June-July, the median age of positive people was 35.8 years (IQR: 24.0-50.2). The positivity rate of patients under 50 increased from 6.0 to 10.6 percent and the positivity rate for those over 50 decreased from 6.3 to 5.0 percent between the early and late periods. The trend was only observed for outpatient populations. CONCLUSIONS: We confirm that there is a trend toward decreasing age among persons with laboratory-confirmed SARS-CoV-2 infection, but that these trends seem to be specific to the outpatient population. Overall, this suggests that observed age-related trends are driven by changes in testing patterns rather than true changes in the epidemiology of SARS-CoV-2 infection. This calls for caution in interpretation of routine surveillance data until testing patterns stabilize.


Subject(s)
Clinical Laboratory Techniques/statistics & numerical data , Coronavirus Infections/epidemiology , Epidemiological Monitoring , Pneumonia, Viral/epidemiology , Adolescent , Adult , Age Distribution , Aged , Aged, 80 and over , COVID-19 , COVID-19 Testing , Child , Child, Preschool , Clinical Laboratory Techniques/standards , Coronavirus Infections/diagnosis , Humans , Infant , Middle Aged , Pandemics , United States
7.
bioRxiv ; 2020 Sep 21.
Article in English | MEDLINE | ID: covidwho-808493

ABSTRACT

Antibody neutralization is an important prognostic factor in many viral diseases. To easily and rapidly measure titers of neutralizing antibodies in serum or plasma, we developed pseudovirion particles composed of the spike glycoprotein of SARS-CoV-2 incorporated onto murine leukemia virus capsids and a modified minimal MLV genome encoding firefly luciferase. These pseudovirions provide a practical means of assessing immune responses under laboratory conditions consistent with biocontainment level 2.

SELECTION OF CITATIONS
SEARCH DETAIL